2017

Der Unfallchirurg

A new continuous gait analysis system for ankle fracture aftercare

B. J. Braun, N. T. Veith, S. C. Herath, R. Hell, M. Rollmann, M. Orth, J. H. Holstein, T. Pohlemann

Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinikum des Saarlandes

Schlagwörter

aftercare, ankle fracture, plantar pressure

aftercare, ankle fracture, plantar pressure

Zusammenfassung

Background Correct aftercare following lower extremity fractures remains a controversial issue. Reliable, clinically applicable weight-bearing recommendations have not yet been defined. The aim of the current study was to establish a new gait analysis insole during physical therapy aftercare of ankle fractures to test patients’ continuous, long-term compliance to partial weight-bearing restrictions and investigate whether patients can estimate their weight-bearing compliance. Materials and Methods The postoperative gait of 14 patients after operative treatment of Weber B-type ankle fractures was monitored continuously for six weeks (OpenGO, Moticon GmbH, Munich). All patients were instructed and trained by physical therapists on how to maintain partial weight-bearing for this time. Discontinuous (three, six and twelve weeks) clinical (patient questionnaire, visual analogue pain score [VAS]) and radiographic controls were performed. Results Despite the set weight-bearing limits, individual ranges for overall weight-bearing (range 5–107% of the contralateral side) and patient activity (range 0–366 min/day) could be shown. A good correlation between weight-bearing and pain was seen (rs = −0.68; p = <0.0001). Patients significantly underestimated their weight-bearing time over the set limit (2.3 ± 1.4 min/day vs. real: 12.6 ± 5.9 min/day; p < 0.01). Conclusions Standardized aftercare protocols and repeated training alone cannot ensure compliance to postoperative partial weight-bearing. Patients unconsciously increased weight-bearing based on their pain level. This study shows that new, individual and possibly technology-assisted weight-bearing regimes are needed. The introduced measuring device is feasible to monitor and steer patient weight-bearing during future studies.

Moticon's Schlussfolgerungen

This study addresses the contentious issue of appropriate aftercare following lower extremity fractures, specifically ankle fractures, and the lack of reliable weight-bearing guidelines. Specifically, it was aimed to evaluate Moticon’s OpenGo sensor insole for monitoring compliance with partial weight-bearing restrictions. Fourteen patients with Weber B-type ankle fractures were continuously monitored postoperatively for six weeks using the OpenGo system. Patients were trained to maintain partial weight-bearing, with periodic clinical and radiographic evaluations. Results showed a wide range in weight-bearing and activity levels, revealing that patients significantly underestimated their weight-bearing time. There was a strong correlation between weight-bearing and pain. The study concludes that standardized protocols and training are insufficient for ensuring compliance, as patients tend to increase weight-bearing unconsciously according to pain levels. The findings suggest the need for individualized, technology-assisted weight-bearing regimes, highlighting the feasibility of the introduced sensor insoles for future studies.

Kontaktiere uns
Buche eine kostenlose Online-Demo oder verwende das Kontaktformular, um mit uns in Kontakt zu treten.
Newsletter
Trage Dich in unseren Newsletter ein, um regelmäßige Updates zu erhalten
Verwendete Produkte von Moticon

Select your desired system

The cutting edge test based outcome assessment system for health professionals and trainers

The most versatile toolkit for free data acquisition and comprehensive analytics in research

Have a general inquiry?

Write us a message for general questions about products and solutions or if you’d like to discuss other topics.


Wähle Deine Produktelinie

Mobile Ganganalysen und sportmotorische Tests für Trainer und Therapeuten – objektiv und effizient.

Das flexible System für freie Datenerfassung und fortgeschrittene Analysen in der Forschung.

Du möchtest eine Anfrage stellen?

Schreibe uns eine Nachricht zu allgemeinen Fragen über Produkte oder zu anwendungsbezogenen Themen, die Du besprechen möchtest.


Das Formular wurde erfolgreich gesendet.

Wir werden uns in Kürze mit dir in Verbindung setzen.

moticon-rego-sensor-insole-live-event

Immer einen Schritt voraus!

Abonniere unseren Newsletter für die neuesten Informationen zu Fallstudien, Webinaren, Produkt-Updates und Neuigkeiten bei Moticon

Hole dir Unterstützung

Finde Antworten zu den häufigsten Fragen in unseren FAQ

Beschreibe Dein Problem so detailliert wie möglich. Hänge Screenshots oder Daten an, sofern das hilfreich ist.


Need help?
Want a live demo?
Interested in prices?
Want to say hello?
Always just a call away
+49 89 2000 301 60
Du brauchst Unterstützung?
Du möchtest eine Live Demo?
Interessiert an Preisen?
Du hast Fragen?
Nur einen Anruf entfernt
+49 89 2000 301 60

The form was sent successfully.

You will be contacted shortly.

Get support

Check our FAQ database for answers to frequently asked questions

Describe your issue in as much detail as possible. Include screenshots or files if applicable.