Kontakt
Du brauchst Unterstützung?
Für technische Fragen zu Moticon Produkten
Du hast Fragen?
Sende uns hier eine Nachricht zu generellen Fragen
Du möchtest eine Demo?
Erlebe unsere Produkte in Aktion und stelle Frage
Interessiert an Preisen?
Erhalte ein individuelles Angebot für Deine Produktwahl
Nur einen Anruf entfernt
+49 89 2000 301 60

Archive of Applied Mechanics

| 2019

An individualized simulation model based on continuous, independent, ground force measurements after intramedullary stabilization of a tibia fracture

The interfragmentary movement (IFM) is a key determinant for the fracture healing process. Different simulation models allow the prediction of the IFM in the fracture gap based on an estimated ground force. For this purpose, a workflow capable for implementation into the clinical routine workup was developed as a proof of concept based on individualized IFM simulations. Starting with clinical X-ray image data, a personalized computational model of the tibial shaft fracture and the intramedullary stabilization was set up in a computer-aided design system, assigned with material parameters, equipped with patient-specific boundary conditions and passed to finite element simulations. We obtained continuously measured postoperative patient gait data from a novel pedobarography insole, mapped the gait data onto an OpenSim gait model and used the resulting forces as input for the simulation of the IFM during a step forward and a step downstairs. In order to verify the simulation results with respect to the IFM, a series of different configurations for the bone material parameters are tested combined with different levels of mesh discretization. The results show IFM values comparable in range to simulation results based on validated OrthoLoad data for even surface gait as well as during walking downstairs. The computed shear movements in the coronal and the sagittal planes were low, and a complete fracture healing of the patient was observed after 6months. The presented simulation-based workflow can determine the patients’ weight-bearing specific interfragmentary movement after an intramedullary stabilization of a tibial shaft fracture.

Keywords

Interfragmentary move, Patient-specific simulations, Continuously measured gait data, Tibial fracture, Intramedullary nailing

Author/s

Benedikt J. Braun, Tim Pohlemann, Steven C. Herath, Moritz Klein, Mika F. Rollmann, Ralf Derr, Stefan Diebels, Michael Roland

Institution / Department

Chair of Applied Mechanics, Saarland University, Saarbrücken

Das Formular wurde erfolgreich gesendet.

Wir senden in Kürze eine Benachrichtigung.

moticon-rego-sensor-insole-live-event

Sei immer einen Schritt voraus!

Abonniere unseren Newsletter für die neuesten Informationen zu Fallstudien, Webinaren, Produkt-Updates und Neuigkeiten bei Moticon

Supportanfrage

Finde Antworten zu den häufigsten Fragen in unseren FAQ


Beschreibe Dein Problem so detailliert wie möglich. Hänge Screenshots oder Daten an, sofern das hilfreich ist.


Du möchtest eine Anfrage stellen?

Schreibe uns eine Nachricht zu allgemeinen Fragen über Produkte oder zu anwendungsbezogenen Themen, die Du besprechen möchtest.