Assymetry of foot pressure for transfemoral amputees during gait in real world

Jeicheong Ryu, Jin-Ho Son, Gyoosuk Kim, Sungjae Kang, Chang-Yong Ko

Rehabilitation Engineering Research Institute of KCOMWEL

Schlagwörter

amoutee, gait analysis, plantar pressure

amoutee, gait analysis, plantar pressure

Zusammenfassung

INTRODUCTION The prosthetic socket is the most important compartment of the prostheses for transfemoral amputees [1]. Nowadays, the ischial containment socket (ICS) and anatomical socket (ANA) have been widely used as prosthetic socket for transfemoral amputee. Some studies have showed differences of biomechanical features between the sockets, such as range of motion of lower limb. Although transfemoral amputees are characterized by gait asymmetry, there have been few studies that investigated gait asymmetry during a gait in real-world environments. The aim of this study was to assess asymmetry of foot plantar pressure in transfemoral amputees during a gait in real-world environment considering prosthetic sockets (ICS) METHODS Seven male transfemoral amputees (174.1 ± 3.9 cm, 81.4 ± 11.0 kg, 46.0 ± 8.8-year-old, # of ICS: 3, # of ANA: 4) and 10 male healthy young adults (176.9 ± 2.5 cm, 72.3 ± 7.9 kg, 24.4 ± 2.0-year-old) were enrolled. A wearable foot pressure insole sensor was placed in the shoe (OpenGO science, Moticon, Germany). Participants were asked to walk at self-selected velocity in real-world environments that consisted of level, slope, stair and uneven terrain for a distance of about 1.6 km (Figure 1.). Asymmetry of foot plantar pressure and temporal parameters between sound and amputated feet and between left and right feet were calculated. RESULTS AND DISCUSSION Figure. 1 shows the comparison of symmetry of plantar pressure. Transfemoral amputees had higher asymmetry as compared with non-amputee participants. Significantly higher asymmetry in ICS was observed, while no significant differences between non-amputee and ANA was shown. Although there was tendency for greater asymmetry of stance phase in transfemoral amputee, (7.3 % in ICS, 6.4 % in ANA) than non-amputees (3 %), no significant differences were observed among groups (p > 0.05). Significantly larger asymmetry of double stance phase was observed in transfemoral amputees (p 0.05). These results indicate that asymmetry in transfemoral amputees during walking in real-world environments is larger than for non-amputees. Furthermore, the tranfemoral socket types appear to affect the magnitude of asymmetry. In this study, only a few trasnfemoral amputees were involved which will have impacted the statistical power. Further studies with more subjects are needed. Figure 1: Terrains on real environment and comparison of symmetry of plantar pressure, *: p < 0.05. CONCLUSIONS In this study, the asymmetry between sound and amputated limb in transfemoral amputees during walking in real-world environments was evaluated. We confirmed a higher asymmetry in transfemoral amputees. Furthermore, socket type affected the asymmetry. ACKNOWLEDGEMENTS This work was supported by the Industrial Strategic Technology Development Program (No.10048732, Development of Smart Musculoskeleton Substitution Device for Functional Recovery and Assistance of Lower Lim) funded by the Ministry of Trade, Industry & Energy(MI, Korea)

Moticon's Schlussfolgerungen

This study aimed to assess gait asymmetry in transfemoral amputees using different prosthetic sockets (Ischial Containment Socket (ICS) and Anatomical Socket (ANA)) in real-world environments. Seven male transfemoral amputees and ten healthy controls participated, using Moticon sensor insoles while walking 1.6 km across varied terrains. Results indicated higher plantar pressure asymmetry in transfemoral amputees compared to controls, particularly with the ICS. No significant differences were observed between non-amputees and those using ANA sockets. Despite a trend towards greater stance phase asymmetry in amputees, statistical significance was lacking. Larger asymmetry was noted in the double stance phase for amputees. The study concludes that prosthetic socket type impacts gait asymmetry, highlighting the need for further research with larger participant groups to enhance statistical power.

Kontaktiere uns
Buche eine kostenlose Online-Demo oder verwende das Kontaktformular, um mit uns in Kontakt zu treten.
Newsletter
Trage Dich in unseren Newsletter ein, um regelmäßige Updates zu erhalten
Verwendete Produkte von Moticon

Select your desired system

The cutting edge test based outcome assessment system for health professionals and trainers

The most versatile toolkit for free data acquisition and comprehensive analytics in research

Have a general inquiry?

Write us a message for general questions about products and solutions or if you’d like to discuss other topics.


Wähle Deine Produktelinie

Mobile Ganganalysen und sportmotorische Tests für Trainer und Therapeuten – objektiv und effizient.

Das flexible System für freie Datenerfassung und fortgeschrittene Analysen in der Forschung.

Du möchtest eine Anfrage stellen?

Schreibe uns eine Nachricht zu allgemeinen Fragen über Produkte oder zu anwendungsbezogenen Themen, die Du besprechen möchtest.


Das Formular wurde erfolgreich gesendet.

Wir werden uns in Kürze mit dir in Verbindung setzen.

moticon-rego-sensor-insole-live-event

Immer einen Schritt voraus!

Abonniere unseren Newsletter für die neuesten Informationen zu Fallstudien, Webinaren, Produkt-Updates und Neuigkeiten bei Moticon

Hole dir Unterstützung

Finde Antworten zu den häufigsten Fragen in unseren FAQ

Beschreibe Dein Problem so detailliert wie möglich. Hänge Screenshots oder Daten an, sofern das hilfreich ist.


Need help?
Want a live demo?
Interested in prices?
Want to say hello?
Always just a call away
+49 89 2000 301 60
Du brauchst Unterstützung?
Du möchtest eine Live Demo?
Interessiert an Preisen?
Du hast Fragen?
Nur einen Anruf entfernt
+49 89 2000 301 60

The form was sent successfully.

You will be contacted shortly.

Get support

Check our FAQ database for answers to frequently asked questions

Describe your issue in as much detail as possible. Include screenshots or files if applicable.