Quantifying Postural Load in the Operating Room: Moticon Sensor Insoles Evaluate Surgical Ergonomics

Continuous, unobtrusive monitoring in real operating room environments reveals key differences in standing patterns and asymmetrical loading between open and laparoscopic surgery.
October 12, 2026
Doctors performing surgery

Topics in this article

Summary

A clinical study conducted by researchers at the University of Cagliari evaluated the feasibility of real-world postural and balance monitoring during surgical procedures using Moticon’s OpenGo wireless sensor insoles. By capturing ground reaction forces and foot kinematics directly in the operating room, the study provides objective insights into standing behavior, load asymmetry, and micro-adjustments among surgeons performing open and laparoscopic procedures.

Why surgical ergonomics and posture monitoring matter

Prolonged static standing – defined as maintaining an upright posture for extended periods with minimal movement – is a major occupational health hazard associated with work-related musculoskeletal disorders, severe discomfort, lower-extremity strain, and physical fatigue (1, 2). Surgeons represent a particularly vulnerable group because surgical operations demand high precision and fixed body positions over extended periods (3, 4). Unlike dynamic standing, static standing limits the lower-leg muscle pump, impairing blood circulation and accelerating localized fatigue (5, 6). Over time, these physical demands affect surgeon health and quality of life while potentially compromising surgical focus and performance (7). Although both open and laparoscopic surgeries present distinct physical demands, objective data quantifying standing patterns and postural stress in actual operating room environments have remained scarce.

Challenges in evaluating standing posture in real surgical environments

Assessing postural load during actual surgical procedures presents significant methodological hurdles:

  • Intrusive Laboratory Setup: Traditional motion capture, surface electromyography, and force plates are expensive, restrictive, and impossible to deploy seamlessly in operating rooms.  
  • Subjectivity of Self-Reports: Questionnaires and observational tools rely on retrospective or subjective evaluations.
  • Long Procedure Durations: Monitoring requires an unobtrusive solution capable of storing data across multi-hour shifts without interrupting surgical workflows (8). 

Sensor insoles enable real-world operating room monitoring

To overcome these constraints, researchers at the University of Cagliari deployed Moticon’s wireless OpenGo  Sensor Insoles which recorded 16-sensor plantar pressure distributions and 3-axis acceleration signals. The system’s onboard storage enabled up to 2.5 hours of continuous data logging per session without external interference. Using custom analytical algorithms, ground reaction forces and movement signals were processed to separate dynamic stepping from static standing, classify standing bout durations, and measure lower-limb loading asymmetry, fidgeting, and weight shifts.

Fig-1: Vertical ground reaction forces (vGRF) for the left (red) and right (green) feet during a surgical procedure, illustrating stepping and static standing phases.

Achievements and clinical findings

The study monitored 18 surgeons across 10 laparoscopic and 8 open surgical procedures, yielding key biomechanical insights:  

  • Standing Time Distribution: Open surgeries involved significantly higher static standing time (>90% of total procedure duration) compared to laparoscopic procedures (~64%).  
  • Static Bout Durations: Open surgeries were dominated by prolonged uninterrupted standing bouts exceeding 10 minutes, whereas laparoscopic procedures exhibited more fragmented standing patterns with numerous short bouts (<5 minutes).  
  • Load-Bearing Asymmetry: Both surgical approaches demonstrated severe load asymmetry: Surgeons supported more than 80% of their body weight on a single limb during roughly 30% of total static standing time.  
  • Micromovement Strategies: Weight shifts and fidgeting events occurred at comparable rates across both surgical types, functioning as spontaneous compensatory mechanisms to relieve localized muscle and joint strain (8).

Wrap Up

The study confirms that Moticon’s OpenGo sensor insoles provide an objective, unobtrusive method for assessing standing-related biomechanics in live operating rooms and, more broadly speaking, in work environments with prolonged standing periods. By quantifying static load exposure, duration patterns, and postural asymmetry, this technology supports the development of targeted ergonomic interventions – such as micro-breaks and anti-fatigue solutions – to protect surgical staff from work-related musculoskeletal overload.

References

  1. EU-OSHA (European Agency for Safety and Health at Work). Musculoskeletal disorders and prolonged static standing. OSHwiki.
  2. Waters, T. R., & Dick, R. B. (2015). Evidence of health risks associated with prolonged standing at work and intervention effectiveness. Rehabilitation Nursing, 40(3), 148–165.
  3. Rătu, A. L., Barac, S., Gârleanu, L. L., & Onofrei, R. R. (2021). Work-related musculoskeletal complaints in surgeons. Healthcare, 9(11), 1482.
  4. Gorce, P., & Jacquier-Bret, J. (2024). Work-related musculoskeletal disorders among surgeons: a bibliometric analysis from 1982 to 2024. Exploration of Musculoskeletal Diseases, 2, 317–335.
  5. Garcia, M.-G., Läubli, T., & Martin, B. J. (2015). Long-term muscle fatigue after standing work. Human Factors, 57(7), 1162–1173.
  6. Verma, A., Garg, A., Xu, D., et al. (2017). Skeletal muscle pump drives control of cardiovascular and postural systems. Scientific Reports, 7, 45301.
  7. Plerhoples, T. A., Hernandez-Boussard, T., & Wren, S. M. (2012). The aching surgeon: a survey of physical discomfort and symptoms following open, laparoscopic, and robotic surgery. Journal of Robotic Surgery, 6(1), 65–72.
  8. Porta, M., Casu, G., Arippa, F., Campagna, M., & Pau, M. (2026). Feasibility of Insole-Derived Plantar Pressure Measures for Evaluating Standing-Related Parameters in Open and Laparoscopic Surgery. In V. G. Duffy (Ed.), Digital Human Modeling and Applications in Health, Safety, Ergonomics and Risk Management (LNCS 16720, pp. 36–48). Springer, Cham.

Get in Touch - We're Waiting for You!

The form was sent successfully.

You will be contacted shortly.

You Would Like to Get in Touch?

Write us a message on product related questions or with regards to your application.  We are here to assist!


Schedule an Online Demo

Get a hands-on overview of our products, find the best choice, discuss your application and ask questions.

30 minutes

Web conferencing details will be provided upon confirmation

You are currently viewing a placeholder content from Google Calendar. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.

More Information

Stay one step ahead!

Subscribe to our newsletter for the latest information on case studies, webinars, product updates and company news

Get Support

Check our FAQ database for answers to frequently asked questions

Describe your issue in as much detail as possible. Include screenshots or files if applicable.